SINGLE REDUCTION BASE TYPE GEAR DRIVES

     
Average Shipping Weight:  65 Lbs.
Right click on link to download CAD drawing:  BASETYPE.dxf  

NOTE:  Bracketed numbers in table below refer to Notes section below table.

MODEL

RATIO (2)

RATINGS (1)

GEARBOX (4) INERTIA (LB-FT 2)

DIA A. (INCHES)

OUTPUT (RPM)

INPUT HORSEPOWER

OUTPUT TORQUE (IN-LB)

INPUT SHAFT (3) OVERHUNG LOAD CAPACITY (LBS)

OUTPUT SHAFT (3) OVERHUNG LOAD CAPACITY (LBS)

9013 (5)

1.315

1331

79.2 (6)

3750

75

500

0.13

1 1/4

9015 (5)

1.551

1128

70.9 (6)

3960

75

500

0.11

1 1/4

9019 (5)

1.907

918

59.7 (6)

4100

75

500

0.10

1 1/4

9020 (5)

2.049

854

55.6

4100

75

500

0.09

1 1/4

9022 (5)

2.205

794

51.6

4100

75

500

0.08

1 1/4

9024 (5)

2.378

736

47.7

4090

75

500

0.08

1 1/4

9028 (5)

2.788

628

39.6

3980

150

1000

0.05

1 1/4

9030

3.032

577

36.0

3930

150

1000

0.04

1 1/4

9033

3.310

529

32.5

3870

150

1000

0.04

1 1/4

9036

3.630

482

29.3

3830

150

1000

0.04

1 1/4

9040

4.000

438

25.2

3630

200

1000

0.03

1 1/4

9042

4.208

416

23.6

3580

200

1000

0.03

1 1/4

9044

4.435

395

22.0

3510

200

1000

0.03

1 1/4

9047

4.682

374

20.2

3410

325

1000

0.03

1 1/4

9049

4.952

353

18.8

3360

325

1000

0.03

1 1/4

9052

5.250

333

17.6

3330

450

1000

0.02

1 1/8

9056

5.579

314

15.9

3200

450

1000

0.02

1 1/8

9059

5.944

294

14.5

3110

400

1000

0.02

1

9063

6.353

275

13.1

3000

400

1000

0.02

1

9068

6.813

257

12.0

2930

400

1000

0.02

1

NOTES

  1. Horsepower, torque, output speed and overhung load capacities based on 1750 rpm input speed and 1.00 Service Factor.

  2. Non-standard ratios available.  Consult Dorris Company if desired ratio is not shown.

  3. Overhung load is measured at the midpoint of the key for the input and output shafts respectively.

  4. Measured at the input shaft.

  5. If a backstop is required consult Dorris Company for backstop torque capacity as it is less than the output torque rating shown.

  6. Consult Dorris Company for thermal capacity in your application.

 

Copyright © 2006 Dorris Company, Inc. All rights reserved.   Contact the webmaster about this web site!