8500 Series
Home Up

8500 Series  (Download 8500 Series *.pdf file)

SINGLE & DOUBLE
REDUCTION BASE TYPE GEAR DRIVES

     
Average Shipping Weight:  475 Lbs.
Right click on link to download CAD drawing:  BASETYPE.dxf  

NOTE:  Bracketed numbers in table below refer to Notes section below table.




MODEL





RATIO (2)





REDUCTION (3)

RATINGS (1)

 


GEARBOX (5) INERTIA (LB-FT 2)

 

 

DIA A. (INCHES)

 

 

KEYWAY B




OUTPUT (RPM)




INPUT HORSEPOWER

OUTPUT TORQUE (IN-LB)

INPUT SHAFT (4) OVERHUNG LOAD CAPACITY (LBS)

OUTPUT SHAFT (4) OVERHUNG LOAD CAPACITY (LBS)

85055S (6)

5.529

SINGLE

316

197.0 (7)

39,200

1120

6430

0.42

1 7/8

1/2

85058 (6)

5.789

DOUBLE

302

201.0 (7)

42,000

1120

6430

1.43

2

1/2

8513

13.034

DOUBLE

134

89.5 (7)

42,000

1120

6430

0.24

2

1/2

8515

15.238

DOUBLE

115

76.5 (7)

42,000

1120

6430

0.20

2

1/2

8518

17.893

DOUBLE

98

64.6

41,600

1120

6430

0.17

2

1/2

8520

19.722

DOUBLE

89

56.6

40,200

1120

6430

0.16

1 1/2

3/8

8524

24.457

DOUBLE

72

47.6

41,900

930

6430

0.14

2

1/2

8526

26.191

DOUBLE

67

44.4

41,900

930

6430

0.13

1 1/2

3/8

8527

26.956

DOUBLE

65

43.2

41,900

690

6430

0.12

1 1/2

3/8

8530

29.909

DOUBLE

58

39.0

42,000

690

6430

0.12

1 1/2

3/8

85334

33.453

DOUBLE

52

34.9

42,000

690

6430

0.11

1 1/2

3/8

8535

35.319

DOUBLE

50

31.5

40,100

690

6430

0.11

1 1/4

1/4

8540

40.332

DOUBLE

43

28.7

42,000

690

6430

0.11

1 1/4

1/4

NOTES

  1. Horsepower, torque, output speed and overhung load capacities based on 1750 rpm input speed and 1.00 Service Factor.

  2. Non-standard ratios available.  Consult Dorris Company if desired ratio is not shown.

  3. Single reduction high speed shaft dimensions shown in parentheses ( ).

  4. Overhung load is measured at the midpoint of the key for the input and output shafts respectively.

  5. Measured at the input shaft.

  6. If a backstop is required consult Dorris Company for backstop torque capacity as it is less than the output torque rating shown.

  7. Consult Dorris Company for thermal capacity in your application.

 

Copyright © 2006 Dorris Company, Inc. All rights reserved.   Contact the webmaster about this web site!