5800 Series
Home Up

5800 Series  (Download 5800 Series *.pdf file)

SINGLE & DOUBLE
REDUCTION BASE TYPE GEAR DRIVES

     
Average Shipping Weight:  363  Lbs.
Right click on link to download CAD drawing:  BASETYPE.dxf  

NOTE:  Bracketed numbers in table below refer to Notes section below table.




MODEL





RATIO (2)





REDUCTION (3)

RATINGS (1)

 


GEARBOX (5) INERTIA (LB-FT 2)

 

 

DIA A. (INCHES)

 

 

KEYWAY B




OUTPUT (RPM)




INPUT HORSEPOWER

OUTPUT TORQUE (IN-LB)

INPUT SHAFT (4) OVERHUNG LOAD CAPACITY (LBS)

OUTPUT SHAFT (4) OVERHUNG LOAD CAPACITY (LBS)

5804S (6)

4.046

SINGLE

432

140.0 (7)

20,500

1875

4650

0.58

1 3/4

3/8

5805 (6)

5.070

DOUBLE

345

117.0 (7)

21,500

1875

4650

0.90

2

1/2

5807

6.665

DOUBLE

263

89.6 (7)

21,500

1875

4650

0.70

2

1/2

5808

8.109

DOUBLE

216

73.6 (7)

21,500

1875

4650

0.60

2

1/2

5809

9.324

DOUBLE

188

65.8 (7)

22,090

1875

4650

0.50

2

1/2

5811

10.826

DOUBLE

162

56.4 (7)

22,000

1875

4650

0.40

2

1/2

5812

12.207

DOUBLE

143

50.0

22,000

1875

5450

0.30

2

1/2

5815

15.215

DOUBLE

115

38.9

21,310

1875

5450

0.20

2

1/2

5818

18.607

DOUBLE

94

31.3

21,000

900

6000

0.15

1 1/2

3/8

5820

19.657

DOUBLE

89

29.0

20,500

900

6000

0.14

1 1/2

3/8

5821

20.812

DOUBLE

84

26.7

20,000

900

6000

0.12

1 1/2

3/8

5822

22.088

DOUBLE

79

24.5

19,490

900

6000

0.09

1 3/8

3/8 (8)

5823

23.276

DOUBLE

75

23.0

19,280

900

6000

0.09

1 3/8

3/8 (8)

5825

24.771

DOUBLE

71

23.0

20,500

900

6000

0.08

1 3/8

3/8 (8)

5826

25.976

DOUBLE

67

23.0

21,500

900

6000

0.08

1 3/8

3/8 (8)

5829

29.508

DOUBLE

59

19.1

20,250

650

6300

0.08

1 1/4

1/4

5835

35.319

DOUBLE

50

17.1

21,700

650

6300

0.07

1 1/4

1/4

5840

40.332

DOUBLE

43

14.1

20,500

650

6300

0.07

1 1/4

1/4

NOTES

  1. Horsepower, torque, output speed and overhung load capacities based on 1750 rpm input speed and 1.00 Service Factor.

  2. Non-standard ratios available.  Consult Dorris Company if desired ratio is not shown.

  3. Single reduction high speed shaft dimensions shown in parentheses ( ).

  4. Overhung load is measured at the midpoint of the key for the input and output shafts respectively.

  5. Measured at the input shaft.

  6. If a backstop is required consult Dorris Company for backstop torque capacity as it is less than the output torque rating shown.

  7. Consult Dorris Company for thermal capacity in your application.

  8. Non-standard keyway.

 

Copyright © 2006 Dorris Company, Inc. All rights reserved.   Contact the webmaster about this web site!